Last Code Revision Date: 03-Sep-2025
This project bridges OPC UA servers and MQTT brokers, allowing you to read values from OPC UA nodes and publish them to MQTT topics. It is designed for industrial automation, IIoT, and SCADA integration.
You can install all required packages using the provided requirements.txt
file:
pip install -r requirements.txt
Package | Version | Notes |
---|---|---|
asyncua | 1.1.6 | Async OPC UA client |
gmqtt | 0.7.0 | Async MQTT client |
aiofiles | 24.1.0 | Async file I/O |
aiosqlite | 0.21.0 | Async SQLite access |
cryptography | 45.0.6 | >42.0.0 — TLS & security |
pyopenssl | 25.1.0 | >23.2.0 — SSL/TLS support |
python-dateutil | 2.9.0.post0 | Date/time utilities |
pytz | 2025.2 | Timezone support |
sortedcontainers | 2.4.0 | Fast sorted collections |
typing-extensions | 4.15.0 | Typing enhancements |
cffi | 1.17.1 | ≥1.14 — C interface for Python |
pycparser | 2.22 | C parser for cffi |
six | 1.17.0 | ≥1.5 — Python 2/3 compatibility |
opcua | 0.98.13 | Synchronous OPC UA client |
paho-mqtt | 2.1.0 | MQTT client (sync) |
lxml | 6.0.1 | XML parsing (used by opcua) |
Edit config.json
to set your OPC UA server, MQTT broker, and node details:
{
"opcua_server_url": "opc.tcp://localhost:4840",
"mqtt": {
"broker": "localhost",
"port": 1883
},
"nodes": {
"Node1": "ns=2;s=Demo.Static.Scalar.Int32",
"Node2": "ns=2;s=Demo.Static.Scalar.String"
},
"interval": 2
}
opcua_server_url
: OPC UA server endpointmqtt.broker
: MQTT broker addressmqtt.port
: MQTT broker portnodes
: Dictionary of MQTT topic names to OPC UA node IDsinterval
: Polling interval in secondspip install -r requirements.txt
config.json
as needed.python main.py
When you run the script, you should see console messages like:
Connected to MQTT broker: 127.0.0.1:1883
Connected to OPC UA server: opc.tcp://localhost:4840
Published initial value for Node1: 42
Published initial value for Node2: Hello
Published updated value for Node1: 43
Published updated value for Node2: World
MQTT disconnected (rc=1). Attempting to reconnect...
MQTT reconnected successfully.
OPC UA connection lost. Attempting to reconnect...
Connected to OPC UA server: opc.tcp://localhost:4840
On the MQTT broker, you will see topics updated with the latest values from the OPC UA nodes, for example:
Node1
receives payloads like 42
, 43
, etc.Node2
receives payloads like Hello
, World
, etc.Error messages will be printed if connections drop or node reads fail, and the script will attempt to reconnect automatically.